Adept HPLC Instrument Specifications

HPLC Pump CE 4100
     

Flow Rate

0.001 to 10mL/min in 0.001 steps
Flow Reproducibility
  Better than 0.1%
Maximum Pressure
  40MPa = 400 bar
User Interface
  4 line back-lit display

  Full range of keys for menu and parameter selection

  Fast number entry keys
Over Pressure Cut-out
  Adjustable between 3 and 40MPa
Low Pressure Cut-out
  Adjustable between 0 and 40MPa
Material in contact with fluids
  Ceramic inserts - biocompatible

  Check valves – ruby & sapphire
Pulsation
  Better than ±0.5% at 2mL/min
Size & Weight
  365 x 290 x 140mm, 7.5kg.
Power Requirements   115V or 230V, 50/60Hz, 30VA
     
 
Dual Wavelength, Scanning UV Visible Detector CE 4200
 

All specifications as for the CE 4201 with the following additional specifications

 
Noise   ±0.35 x 10-5 A at 230nm, 2s, using air test cell
Drift   ±0.3 x 10-4 A at 230nm, 2s, using air test cell
Dual Wavelength Operation
  Simultaneous measurements at 2 wavelengths.
Output of absorbance ratio for the 2 wavelengths
Noise, Dual Wavelength
  ± 2 x 10-5 A peak to peak 230/280nm 1s time constant
Drift, Dual Wavelength   ± 1 x 10-4 A/hour at constant temperature
Programmed Operation   Programs may be entered to change parameters, operating modes and select up to 6 different wavelengths in any time sequence.
Printer Output   Parallel printer port
     
UV-Visible Detector CE 4201
     
Optical System   Double beam with 1200 lines/mm grating monochromator
Wavelength Range   190-700nm
Wavelength Accuracy   ± 1nm
Wavelength Precision   ± 0.1nm, single wavelength mode
Optical Bandwidth   8nm approximately
Straylight   < .02%, 220nm

Lamp

  Deuterium lamp with elapsed time indicator 1500 hours or 1 year warranty
Absorbance Range   0.001 to 2A full scale in 11 ranges
Time Constant   0.1, 0.2, 0.5, 1, 2, 5 and 10 seconds
Display   Four-line display of parameters, menus, prompts, wavelength, absorbance etc.
Fast Number Entry   By use of special number keys
Event Marking   From keypad or by external source
Method Storage   For up to 30 methods, security protected
Second Order Filter   Fast automatic insertion at 370nm
Noise   ± 1 x 10-5 A peak to peak, 220nm, 2s time constant
Drift   ± 1 x 10-4 A/hour at constant temperature
Linearity   Better than 1%, 0.001 – 2A
Automatic Power-up/Off   Pre-programmed from keypad to save warm up time
Sample Flow Cell   8µL x 10mm pathlength – normal
    4µL x 5mm pathlength
    Wetted surfaces PEEK, Teflon and Fused Silica
    Other cells available
Refractive Index Sensitivity   < ± 5 x 10-4 A, water to methanol at 350nm
Flow Rate Sensitivity   < ± 3.5 x 10-3 A, for flow change 1-2mL/min, 300nm
Outputs   Two absorbance outputs and absorbance ratio to recorder. All data available to PowerStream System Manager.
Inputs   Event, autozero
Size and Weight   365 x 290 x 140mm, 17kg
Power Requirements   115V or 230V, 50/60Hz, 50VA
     
Ultra Fast Scanning Detector – CE4300
     
Optical System   Double beam
Monochromator   Littrow with 1200 l/min holographic grating
Wavelength Range   190-700nm
Optical Bandwidth   4nm – constant
Digital Resolution   1nm
Wavelength Accuracy   1nm
Wavelength Reproducibility   0.1nm
Absorbance Range   0 to 3A
Scan Speeds   Up to 1000nm/s
Baseline Flatness   ± 0.002A over most of range
Straylight   <0.02% at 220nm and 340nm
Noise   < ±0.5 x 10–5 A at 230nm, 2s air test cell
Drift   < ±0.5 x 10–5 A at 230nm, at equilibrium using air test cell
Calibration and Test   Automatic at switch-on
Display   Four line display of parameters, menus, prompts, wavelength, absorbance etc.
Number of Peak Scans   Up to 100 peaks for any single elution
Multiple Scans of a Peak   Up to 8 scans of any peak
Scan Trigger   At start, set absorbance value, point of inflection or at maximum
Scan Storage   Up to 100 scans password protected
Method Storage   Up to 30 methods, password protected
Size   365 x 290 x 140mm, 17Kg
Power Requirement   115V or 250V, 50/60Hz, 50VA
     
Refractive Index Detector CE 4700
     
Measuring Ranges   ± 10-4 n
Sensitivity   8 x 10-8 n
Noise   8 x 10-8 n
Time constants   0.1, 0.2, 0.5, 1, 2, 5, 10 seconds
Cell volume   9µL
Outputs   -1V to +1V, 20 bit resolution
Size and weight   360 x 140 x 260mm, 9.5kg
Power requirements   100-250V, 50/60Hz, 6VA
     
Fluorescence Detector Dual Monochromator CE 4500
     
Light Source   10W Xenon flash lamp, frequency programmable
Detector   Photomultiplier
Excitation Monochromator   200-600nm, 12nm optical bandwidth, f 2.5
Emission Monochromator   200-600nm, 12nm optical bandwidth, f 2.5
Wavelength Scanning   Excitation and emission independently programmable
Sensitivity   Better than 100 fg Antracine in Methanol
Programmable Events   All normal functions plus wavelength programming up to 99 steps per program; 99 programs
Input Contact Closures   Autozero, event mark
Analogue Outputs   10mV, 100mV and 1V
Dimensions and Weight   457 x 420 x 160, 17kg
Power Requirements   100/240V, 50/60Hz
     
Fluorescence Detector Filter CE 4501
     
Light Source   10W Xenon flash lamp, frequency programmable
Detector   Photomultiplier
Measuring Ranges   1-2000 mA in 11 ranges
Time Constants   0.1, 0.2, 0.5, 1, 2, 5 seconds
Fluorescence Display   6 digit LED
Flowcell Volume   4, 8 and 24µL others available
Inputs   Autozero, event mark
Outputs   1V and 10mV
Sensitivity   Better than 0.2pg anthracene in methanol
20µL flowcell, 254 excitation, 2 second time constant, 1mL/min flow, lamp flash frequency 50Hz
Dimension and Weight   365 x 381 x 146, 13.6kg.
Power Requirement   115/220V, 50/60Hz
     
Conductivity Detector CE 4710
     
Detector   A.C. synchronous detection, 10kHz frequency
Range   0.01 – 5000 µS in 12 steps
Auto Zero   Offsets up to 10,000 µS
Methods   Up to 10 user defined methods
Heater   25W, vulcanised to aluminium block
Pre-heater   Teflon tubing encased in high thermal mass housing
Cell Temperature   Set at 35ºC. User adjustable ambient to 60ºC
Temperature Precision   ± 0.05ºC
Cell Volume   5µL
Pressure Rating   400psi (2.7 MPa)
Surfaces Contacting Fluid   PEEK and Teflon
Outputs   10mV, 100mV and 1V analogue and RS232
Size and Weight   254 x 305 x 178mm (w.d.h.), 5.9kg
Power   120-240V, 50/60Hz, 100 Watts
     
Electrochemical Detector – CE4720
     
Measuring Range   0.02 – 50nA full scale
Offset Compensation   ±200nA
Time Constant   0.5, 1, 2 and 5s
Cell Volume   1.5µL standard
Size & weight   255 x 310 x 105mm, 5kg
Measuring cell 120 x 110 x 155, 1.5kg
     
Automatic Sample Injector CE4800
     
Number of Samples   128 in 8 x 16 sample tray
Number of Injections per Vial   4 with 10µL loop, 3 with 75µL loop
Injection Precision   < ±0.30 RSD peak area, 10µL injections
Carryover   < 0.25% no rinse, < 0.004% with rinse
Valves and Plumbing   316 s.s., Nitronic 60, PEEK, PTFE,
Vials and Caps   Borosilicate glass and opaque polypropylene.
Low density polyethylene caps
Programming   Storage for 10, 128 step methods
Remote Control   Injection signal input, RS232c
1EEE – 488, 4 user contact closures
Refrigeration Option   4 to 40ºC, ±1ºC setting, ±1ºC precision
Power   80 VA, 200 VA refrigerated, 47/63 Hz
Weight and Size   12.7Kg, 330H x 320W x 540D
     
Column Ovens CE4650 / CE4651
     
Temperature Range   30ºC to 80ºC (CE4651)
5ºC to 60ºC (CE4650)
Temperature Stability   ± 0.2ºC over 24 hours
Power   115V-230V, 150VA, 50Hz (CE4651)
230V, 50Hz (CE4650)
Dimensions & Height   50 x 8 x 10.5cm, 3.2Kg (CE4651)
40 x 10 x 10cm, 4Kg (CE4650)
     
Column Ovens CE 4600 / CE 4601
     
Temperature range   10 degrees C above ambient to 120?C (CE 4600)
    10 degrees C below ambient to 80?C (CE 4601)
Time to stability from ambient  

15 mins to 100?C CE 4600
30 mins to 10?C below ambient CE 4601

Injection/switching valves   Provision for one each type Rheodyne
Solvent leak detector   64 levels, user selectable
Size and weight   190 x 230 x 540mm, 8kg
Power requirements   230V, 50Hz, 550VA or 115V, 60Hz, 550VA
     
Solvent Degassers CE 4020 / CE 4040
     
Number of flow channels   4 (CE4040), 2 (CE 4020)
Flowrate each channel   0.2 - 5mL/min
Gas removal   To better than 1ppm at 1mL/min
Size and weight   120 x 220 x 260mm, 6kg
Power requirements   150V or 230V, 200VA
     
Workstation Computer Specification
     
System Requirements    
  • Personal Computer with Pentium class processor
  • Pentium 200 MHz or better
  • Microsoft Windows XP
  • Microsoft NT 4.0 with service pack 3 or later
  • 64 MB of RAM or more
  • Hard-disk space required: 15 MB
  • CD-ROM drive
  • XGA or higher resolution monitor
  • Monitor resolution 1024 x 768 or better
  • Microsoft Mouse or compatible pointing device
   

Tovatech LLC, 11 Harrison Ct, South Orange, NJ 07079   Phone: 973-913-9734   Fax: 973-327-4774