Select a Nor-Lake Large Capacity Incubator for the best in dry heat and CO2 lab environments
The smart choice when you need a bacteria or biotechnology incubator
- Adjustable temp; microprocessor control - complete environmental control
- Locks and alarms - peace of mind
- With 33 cubic foot capacity - fits all your biotech research
- Stainless steel interior - easy clean up
Whether you're doing hematology studies, biotechnology research, tissue culture growth or other cell or bacteria studies, this lab incubator is what you need
These incubators fit your lab research needs in glass or solid doors, with or without CO2 control. Add optional access ports and interior outlet for the ultimate in biotechnology research in a lab incubator. Add a temperature chart recorder - along with standard alarm logging - for easy recordkeeping.
Features
Temperature Control Stability - Puts You In Control
- Operating Range:
- Adjustable from +5°C above ambient to 70°C on solid door models
- Adjustable from +5°C above ambient to 60°C on glass door models
- Uniformity to ± 0.5°C @ 37°C
- Programmable logic microprocessor controller with LCD display control panel with message center
- Streamlined design optimizes mechanical convection air flow and temperature uniformity
- Programmable ramp soak feature
Security - Peace Of Mind
- Air probe with air temperature Hi/Lo alarms
- 2 levels of user password protection (set points and parameters)
- 100 event alarm logging including date/time stamp and product temperatures
- Data Stored in non-volatile flash memory
- Integrated Hi/Lo alarm tests
- Door ajar alarm with adjustable time period delay
- Power failure alarm
- Over temperature safety limit switch
- Audible and visual Hi/Lo product temperature alarms and remote alarm contacts
- Key lock door
Convenient - Easy Monitoring And Easy Access
- Continuous product temperature display
- Full size door: glass or solid
- Leveling legs
Industrial Quality Construction - Durable And Dependable
- Exterior front, sides, and back are painted white
- Stainless steel interior
- 3 solid stainless steel shelves
Standards Compliance - Tested And Efficient
- UL and C-UL listed
- CE Mark
CFC-Free - For A Cleaner Global Environment
- Cabinet foamed in place with CFC-free high density polyurethane foam insulation
Warranties
- U.S. and Canada: 18 month parts and labor
Options To Meet Your Specific Needs
- CO2 control system
- CO2 range: 0 - 20%
- Inlet pressure: -4 to 25 PSI
- Infrared (IR) sensor
- Integrated with primary controller (Programmable Logic controller)
- Humidity pan: 9 quarts, 20-3/4 x 12-3/4 x 2-1/2", 22 gauge stainless steel
- 2 CO2 inputs
- CO2 tanks/customer supplied, 2 recommended
- 1 CO2 output
- CO2 stability 0.1%
- CO2 auto shutoff upon door opening
- CO2 gas regulator not supplied
- Automatic CO2 tank switchover
- Extra shelves and drawers
- Temperature chart recorder and chart paper
- Field reversible hinge door (solid-door model only)
- Duplex interior electrical outlet (4 amp load)
- RH display
- Stainless steel humidity pan
- RS485 computer interface
- Access port 2" sleeve with cover
Ambient Operating Conditions
- 15°C (59°F) to 40°C (104°F)
- Humidity: 80% RH maximum non-condensing
- Voltage tolerance: 10% rated line voltage
Specifications
| Model |
Glass Door NSHI331WSG/0 |
Solid Door NSHI331WSW/0 |
|---|---|---|
| Size (inches) | 35-7/8 x 31-3/4 x 82-3/4 | 35-7/8 x 31-3/4 x 82-3/4 |
| Size (cm) | 91.1 x 80.6 x 210.1 | 91.1 x 80.6 x 210.1 |
| Storage volume (ft3) | 33.1 | 33.1 |
| Storage volume (m3) | 0.93 | 0.93 |
| Voltage | 115 V 60 Hz (single phase) | 115 V 60 Hz (single phase) |
| Amp draw | 8.7 | 8.7 |
-
Stability Chamber Helps Evaluate Extended-Release Drugs
Anything that helps patients follow their treatment regimen is good. One common example is the idea of reducing the number of pills that a patient needs to take. That is, rather than giving a small dose at 4 hour intervals, you give a larger dose at 8 hour intervals. That doesn’t work, though, if the
-
Measuring Amphibian Defensive Skin Secretions Without Sacrifice
It’s much harder to measure anything when the measurement destroys your sample. If your sample is a living organism, then it’s even more difficult: you have to maintain lots of organisms and then extrapolate the condition of one sacrificed animal to another sacrificed at a different time. It’s even worse when your sample animal is
-
How Do You Treat Heat-Related Symptoms When Everything is Hot?
Just in case you were lacking reasons, here’s one more reason to admire people who serve in the military. This 1994 report from the U.S. Army Research Institute of Environmental Medicine summarizes the experience of an army brigade during a three week simulated battle training exercise. Specifically, the report examines heat stress suffered by the
-
Florida Students Find Mangrove Seedlings Adapt to Light Environment
Everybody knows leaves thrive in the light and starve in darkness. But a good percentage of science is examining things “everybody knows.” That’s at least part of the lesson learned by this group of Florida students who examined the difference between leaves raised in the sunshine and in the shade. They collected a number of
-
Monitoring Navy Harbors for Paint-Derived Contaminant
Once there was an undersea king whose daughter was sick. A grizzled little man promised to heal the daughter if the king would give her to him—unless the king could guess his name. Sam? No. Jubalnox? No. Tributyltin? Yes!!! And the princess lived happily ever after in her undersea castle. Well, that COULD have been